Representative Image

Xylem WTW Ammonia Electrode NH 500/2 with Plug-in Head, Including 3 Exchange Heads and 50 ml Electrolyte Solution

Brand:Xylem WTW

Connection plug

Max. temperature

Min. temperature

Temperature

Type

Membrane

Specifications

Compare models
Connection plug
S7 plug head
Shaft length
120 mm
Max. temperature
50 °C
Min. temperature
0 °C
Shaft Ø
12 mm
Temperature
0 ... 50 °C
Type
NH 500/2
UNSPSC
41115608

Alternative in-stock items

NZ $3219.99

Inc. GST

Available soon

Product description

The Xylem WTW Ammonia Electrode NH 500/2 is designed for highly accurate ammonia ion measurements in a variety of applications. Featuring a plug-in head design, it provides easy electrode replacement and maintenance. The set includes three exchange heads and a 50 ml electrolyte solution, ensuring long-lasting performance and reliable results.

Key Features:

  • Brand: Xylem WTW
  • Electrode Type: Ammonia Electrode NH 500/2
  • Electrode Design: Plug-in head for easy maintenance and electrode exchange
  • Accessories Included: 3 exchange heads and 50 ml electrolyte solution
  • Applications: Suitable for ammonia ion measurement in laboratory and industrial environments
  • Durability: Designed for long-lasting use and reliable performance

The Xylem WTW Ammonia Electrode NH 500/2 is an excellent solution for accurate ammonia ion measurement with convenient maintenance features, ideal for both laboratory and industrial applications.

Downloads

Accessories

Accessories for combination electrodes

ProductTypeLengthMfr#Part#AvailabilityPrice
AS/DIN1 m1081109.040 895In stockNZ $203.10
AS/BNC1 m1081149.040 897NZ $219.08
AS/DIN-33 m1081129.040 896NZ $287.54

Compare similar models

Ammonia electrode NH 500/2 with plug-in head incl. 3 exchange heads and 50 ml electrolyte solution

Manufacturer P/N

106395

Part Number

7.008 136

Manufacturer

Xylem WTW

Connection plug

S7 plug head

Combination electrode F 800 BNC incl. accessoires, 1 m BNC cable

Manufacturer P/N

106666

Part Number

7.623 073

Manufacturer

Xylem WTW

Connection plug

BNC

Combination electrode Ag/S 800 DIN incl. reference electrode R 503/d

Manufacturer P/N

106651

Part Number

6.226 445

Manufacturer

Xylem WTW

Connection plug

DIN

Electrodes Ca 800, DIN, incl. accessories, 1 m DIN cable

Manufacturer P/N

106655

Part Number

6.803 397

Manufacturer

Xylem WTW

Connection plug

DIN

Electrodes CI 800, DIN, incl. accessories, 1 m DIN cable

Manufacturer P/N

106661

Part Number

6.204 775

Manufacturer

Xylem WTW

Connection plug

DIN

Electrodes Br 800, DIN, ion selective
Available soon
Xylem WTW Electrodes BR 800 DIN Ion Selective

NZ $3772.25

Inc. GST

Manufacturer P/N

106653

Part Number

6.225 474

Manufacturer

Xylem WTW

Connection plug

DIN

Electrodes F 800, DIN, incl. accessories, 1 m DIN cable

Manufacturer P/N

106667

Part Number

7.615 487

Manufacturer

Xylem WTW

Connection plug

DIN

Combination electrode NO 800 DIN incl. accessories, 1 m DIN cable

Manufacturer P/N

106675

Part Number

6.204 944

Manufacturer

Xylem WTW

Connection plug

DIN

single-rod measuring chain CN 800 DIN
Available soon
Xylem WTW Single Rod Measuring Chain CN 800 DIN

NZ $3664.99

Inc. GST

Manufacturer P/N

106663

Part Number

7.634 542

Manufacturer

Xylem WTW

Connection plug

DIN

Single-rod measuring chain Cu 800 DIN DIN-cable 1 m.

Manufacturer P/N

106665

Part Number

7.620 500

Manufacturer

Xylem WTW

Connection plug

DIN

Electrodes K 800, DIN, incl. accessories, 1 m DIN cable

Manufacturer P/N

106671

Part Number

7.624 548

Manufacturer

Xylem WTW

Connection plug

DIN

Ion-selective measuring cell NA 800/S7 with S7 plug head
Available soon
Xylem WTW Ion-Selective Measuring Cell NA 800/S7

NZ $1754.90

Inc. GST

Manufacturer P/N

106649

Part Number

6.313 274

Manufacturer

Xylem WTW

Connection plug

S7 plug head

Frequently asked questions

It is designed for highly accurate ammonia ion measurements in a variety of applications. Featuring a plug-in head design, it provides easy electrode replacement and maintenance. The set includes three exchange heads and a 50 ml electrolyte solution, ensuring long-lasting performance and reliable results.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator holds its contents in a dry, sealed atmosphere, protecting moisture-sensitive samples and reagents and cooling heated samples without letting them take up water. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

The separating funnel is the go-to tool for liquid-liquid extraction across New Zealand labs, from universities and Crown Research Institutes to environmental, water and food testing. This guide explains what it is, how it works step by step, the main shapes, and how to pick one, with an interactive process demo and finder.

Read full story

NZ $3219.99

Inc. GST