Product overview

The VACUUBRAND Diaphragm Pump MV 2 NT, four-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. Country-specific power cord versions available on request. Its documented configuration includes electrical supply: 115 V, 50-60 V, 120 V, 60 Hz, connection: US Mains Cable, and pump design: Four-Stage.

Key Features:

  • Brand: VACUUBRAND
  • Model: MV 2 NT
  • Product Type: Diaphragm Vacuum Pump
  • Electrical Supply: 115 V, 50-60 V, 120 V, 60 Hz
  • Connection: US Mains Cable
  • Pump Design: Four-Stage
  • Certification: NRTL: C/US100-115 V/50-60 V
  • Pumping Performance: Improved performance, increased pumping speed and better ultimate vacuum Extend applications with non-aggressive gases whether used in the laboratory or for industrial processes
  • Leak Tightness: Very low leak rate due to enhanced leak-tight tubing connections, resulting in consistent performance characteristics - even after many years of operation. Ideal for analytical applications
  • Diaphragm and Valve Design: made of highly flexible FPM, with fabric-reinforced double diaphragms for improved long term stability
  • Noise and Vibration: Very quiet and ultra low vibration due to compact drive with patented motor drive system. Ideal as a built-in component for sensitive analytical equipment
  • Surface Design: Easy to clean due to smooth surfaces. A robust solution for numerous applications in industrial environments
  • Power Cord Options: Country-specific power cord versions available on request

The VACUUBRAND Diaphragm Pump MV 2 NT, four-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable supports oil-free evacuation and pumping of gases or vapours where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.



Frequently Asked Questions

1. What is the VACUUBRAND Diaphragm Pump MV 2 NT, four-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable used for?

It is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. Country-specific power cord versions available on request.

2. What electrical supply does the VACUUBRAND Diaphragm Pump MV 2 NT, four-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable have?

It has an electrical supply of 115 V, 50-60 V, 120 V, 60 Hz.

3. What connection and pump design does the VACUUBRAND Diaphragm Pump MV 2 NT, four-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable offer?

It offers US Mains Cable, four-Stage, NRTL: C/US100-115 V/50-60 V and improved performance, increased pumping speed and better ultimate vacuum Extend applications with non-aggressive gases whether used in the laboratory or for industrial processes.

4. How does the VACUUBRAND Diaphragm Pump MV 2 NT, four-stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable compare with the KNF LIQUIPORT Diaphragm Liquid Pump NF 1.300 FT.18 S, chemically-resistant from KNF?

For its intended use, the VACUUBRAND model is the better choice, offering an electrical supply of 115 V, 50-60 V, 120 V, 60 Hz. The KNF model offers suitable for aggressive and corrosive liquids and diaphragm technology for reliable, leak-free operation as an alternative, while the VACUUBRAND model's US Mains Cable and four-Stage help make it a strong fit for its intended use.

5. How does the VACUUBRAND Diaphragm Pump MV 2 NT, Four Stage, Certification (NRTL), C/US100 to 115 V/50 to 60 V, 120 V/60 Hz, US Mains Cable compare with the IKA Membrane Vacuum Pump VACSTAR Digital?

For vacuum pump applications, the VACUUBRAND Diaphragm Pump MV 2 NT, Four Stage, Certification (NRTL), C/US100 to 115 V/50 to 60 V, 120 V/60 Hz, US Mains Cable is differentiated by electrical supply 115 V, 50-60 V, 120 V, 60 Hz and connection US Mains Cable. The IKA Membrane Vacuum Pump VACSTAR Digital from IKA is another named option in the same product category. Compare the required specifications, compatibility and workflow requirements before selection.

Product Specifications

  • HS Code #84141089
  • Connection pressure sideG1/4"
  • Connection suction sideKF DN 16
  • Depth328 mm
  • Dimensions (WxDxH)239 x 328 x 198 mm
  • Flow rate2.2 m³/h
  • Height198 mm
  • No. of stages4
  • Plug typeUS
  • TypeMV 2 NT
  • Type of auxiliary energyMains connection
  • Ultimate vacuum0.5 mbar
  • UNSPSC40151502
  • Width239 mm
Variant products