SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel, 4x 1.6/2.3/3.2 mm OD
Representative image only

SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel, 4x 1.6/2.3/3.2 mm OD

Sold by: John Morris Scientific NZ
Available Soon
Part #: 4.680 941Manufacturer #: 320045
Estimated shipping time:Contact us via live chat or via contact us page

NZ $890.52

See the available (11) variant products

Product overview

The SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel is designed to offer safe and efficient solvent waste disposal in laboratories. Compatible with GL45-threaded containers, it provides a closed, odor-free system for collecting HPLC and other liquid waste. The system consists of a funnel with a hinged lid and sealing ring mounted on a SafetyWasteCap, integrated with an exhaust air filter to prevent vapor release. Hose olives made of PP accommodate tubing with inner diameters from 5 to 11.5 mm, while a removable sieve ensures effective filtration. The four integrated ports (1.6/2.3/3.2 mm OD) allow for simultaneous waste line connections, supporting a clean and multi-source disposal setup.

Key Features:

  • Brand: SCAT
  • Model: Universal Waste Hub "JAN"
  • Thread Compatibility: GL45
  • Connection Ports: 4x 1.6/2.3/3.2 mm OD
  • Cap Type: SafetyWasteCap with integrated exhaust air filter
  • Funnel: Hinged lid with sealing ring for vapor-tight operation
  • Filtration: Removable sieve for particulate retention
  • Material: High-grade, chemically resistant construction
  • Hose Compatibility: Hose olives (PP) for tubing I.D. 5 to 11.5 mm
  • Application: Safe disposal of solvent and sample waste from HPLC units and other systems without odor emissions
  • Design: Supports capillary connections for versatile lab use

Scope of Supply:

  • Safety funnel
  • 3 hose olives (NPT 1/8")
  • 3 blind fittings (NPT 1/8")
  • Fittings: 4 x 1.6 mm, 4 x 2.3 mm, 4 x 3.2 mm
  • 4 x blind fittings (UNF 1/4")
  • 1 x blind fitting GL 14
  • Exhaust filter size M

The SCAT Universal Waste Hub "JAN" – GL45 offers a secure and efficient system for solvent waste collection and vapor management, making it an essential safety tool in modern laboratories.



Frequently Asked Questions

1. What is the SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel, 4x 1.6/2.3/3.2 mm OD used for?

It is designed to offer safe and efficient solvent waste disposal in laboratories. Compatible with GL45-threaded containers, it provides a closed, odor-free system for collecting HPLC and other liquid waste. The system consists of a funnel with a hinged lid and sealing ring mounted on a SafetyWasteCap, integrated with an exhaust air filter to prevent vapor release. Hose olives made of PP accommodate tubing with inner diameters from 5 to 11.5 mm, while a removable sieve ensures effective filtration. The four integrated ports (1.6/2.3/3.2 mm OD) allow for simultaneous waste line connections, supporting a clean and multi-source disposal setup.

2. Is the SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel, 4x 1.6/2.3/3.2 mm OD suitable for Safe disposal of solvent and sample waste from HPLC units and other systems without odor emissions?

Yes. It is designed for Safe disposal of solvent and sample waste from HPLC units and other systems without odor emissions, and offers connection ports of 4x 1.6/2.3/3.2 mm OD and 3 hose olives (NPT 1/8") to support this kind of work.

3. What connection ports does the SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel, 4x 1.6/2.3/3.2 mm OD have?

It has connection ports of 4x 1.6/2.3/3.2 mm OD, 3 hose olives (NPT 1/8") and 3 blind fittings (NPT 1/8"), and is supplied under manufacturer part number 320045.

4. What is the SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel, 4x 1.6/2.3/3.2 mm OD made from and what features does it include?

It is made from high-grade, chemically resistant construction. It also offers GL45, safetyWasteCap with integrated exhaust air filter and hinged lid with sealing ring for vapor-tight operation.

5. How does the SCAT Universal Waste Hub "JAN" – GL45 Safety Funnel, 4x 1.6/2.3/3.2 mm OD compare with the Bohlender b.safe Waste Cap B53 with Funnel 2x UNF1/4", 1x GL14, 1x NPT1/8" from Bohlender?

For Safe disposal of solvent and sample waste from HPLC units and other systems without odor emissions, the SCAT model is the better choice, offering connection ports of 4x 1.6/2.3/3.2 mm OD, 3 hose olives (NPT 1/8") and 3 blind fittings (NPT 1/8"). The Bohlender model offers connections of 2x UNF1/4" fittings (for capillaries O.D. 1.6/2.2/3.2 mm), 1x GL14 thread, 1x NPT1/8" hose connection (for tubing I.D. 5.5 to 8 mm) as an alternative, while the SCAT model's GL45 and safetyWasteCap with integrated exhaust air filter help make it a strong fit for Safe disposal of solvent and sample waste from HPLC units and other systems without odor emissions.

Product Specifications

  • HS Code #39269097
  • Capillary connections4
  • Connection for exhaust filter1
  • Hose connections3
  • No. of fittings4x1,6/2,3/3,2 mm
  • No. of olives3
  • ThreadGL 45
  • UNSPSC41115700