Memmert Incubator IF450plus, +20 to +80°C, 449 Litre, Forced Air Circulation, With TwinDISPLAY

Brand:Memmert

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Height int.

Int. Dim. (WxDxH)

Int. width

Max. no. of inserts

Nominal capacity

Rated capacity

Temperature

Type

Weight

Specifications

Compare models
HS Code #
84198998
Depth int.
600 mm
Ext. dim. (WxDxH)
1,224 x 784 x 1,247 mm
Ext. depth
784 mm
Ext. height
1247 mm
Ext. width
1224 mm
Power supply frequency
50/60 Hz
Height int.
720 mm
Int. Dim. (WxDxH)
1,040 x 600 x 720 mm
Int. width
1040 mm
Material inserts
Stainless steel

NZ $21459.67

Inc. GST

Available soon

Product description

The Memmert Incubator IF450plus, +20 to +80°C, 449 Litre, Forced Air Circulation, With TwinDISPLAY is designed for laboratory applications requiring reliable incubation with forced air circulation. This incubator features adjustable fan speed, a sterilization programme for the working chamber, and TwinDISPLAY ControlCOCKPIT with two colour displays for practical laboratory use.

Key Features:

  • Brand: Memmert
  • Product Type: Incubator
  • Model: IF450plus
  • Temperature Range: +20 to +80°C
  • Capacity: 449 Litre
  • Air Circulation: Forced air circulation
  • Fan Speed: Adjustable
  • Sterilization Programme: 4 h/160 °C for sterilization of working chamber
  • Display: TwinDISPLAY ControlCOCKPIT with two colour displays

This Memmert incubator is suitable for laboratories requiring a 449 Litre forced air circulation incubator with +20 to +80°C temperature range, adjustable fan speed, sterilization programme, and TwinDISPLAY control.

Accessories

Special equipment for Universal ovens and Incubators

ProductTypeDescriptionMfr#Part#AvailabilityPrice
E06189Ethernet connection cable 5 m for computer interfaceE061899.867 758In stockNZ $118.44
B33170USB User ID Stick (only for units with TwinDISPLAY)B331706.257 480NZ $744.49
E06192USB Ethernet adapterE061929.867 717NZ $212.71
D00125IQ/OQ document, with device-specific works test data for one free-selectable temperature value, incl. temperature distribution survey at Memmert for 9 measuring points to DIN 12880:2007-05 for model 30, PQ check list as support for validation by cuD001259.867 756NZ $5378.21
D00127IQ/OQ document, with device-specific works test data for one free-selectable temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05 for model 55 - 1060, PQ check list as support for validatiD001279.867 757NZ $7036.39

Compare similar models

Incubator IF450plus +20...+80°C, 449 ltr., laboured air circulation, with TwinDISPLAY

Manufacturer P/N

IF450PLUS

Part Number

9.537 991

Manufacturer

Memmert

Depth int.

600 mm

Incubator IF75plus +20...+80°C, 74 ltr., laboured air circulation, with TwinDISPLAY

Manufacturer P/N

IF75PLUS

Part Number

9.537 987

Manufacturer

Memmert

Depth int.

330 mm

Incubator IF110plus +20...+80°C, 108 ltr., laboured air ciculation, with TwinDISPLAY

Manufacturer P/N

IF110PLUS

Part Number

9.537 988

Manufacturer

Memmert

Depth int.

400 mm

Incubator IF160plus +20...+80°C, 161 ltr., laboured air circulation, with TwinDISPLAY

Manufacturer P/N

IF160PLUS

Part Number

9.537 989

Manufacturer

Memmert

Depth int.

400 mm

Incubator IF750plus +20...+80°C, 749 ltr., laboured air circulation, with TwinDISPLAY

Manufacturer P/N

IF750PLUS

Part Number

9.537 992

Manufacturer

Memmert

Depth int.

600 mm

Incubator IF30plus +20...+80°C, 32 ltr., laboured air circulation, with TwinDISPLAY

Manufacturer P/N

IF30PLUS

Part Number

9.537 985

Manufacturer

Memmert

Depth int.

250 mm

Incubator IF55plus +20...+80°C, 53 ltr., laboured air  circulation, with TwinDISPLAY

Manufacturer P/N

IF55PLUS

Part Number

9.537 986

Manufacturer

Memmert

Depth int.

330 mm

Incubator IF260plus +20...+80°C, 256 ltr., laboured air circulation, with TwinDISPLAY

Manufacturer P/N

IF260PLUS

Part Number

9.537 990

Manufacturer

Memmert

Depth int.

500 mm

Frequently asked questions

It is designed for laboratory applications requiring reliable incubation with forced air circulation. This incubator features adjustable fan speed, a sterilization programme for the working chamber, and TwinDISPLAY ControlCOCKPIT with two colour displays for practical laboratory use.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator holds its contents in a dry, sealed atmosphere, protecting moisture-sensitive samples and reagents and cooling heated samples without letting them take up water. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

The separating funnel is the go-to tool for liquid-liquid extraction across New Zealand labs, from universities and Crown Research Institutes to environmental, water and food testing. This guide explains what it is, how it works step by step, the main shapes, and how to pick one, with an interactive process demo and finder.

Read full story