Representative Image

Macherey-Nagel Capillary Column Optima 1701, ID 0.25 mm, Film Thickness 0.5 µm, Length 60 m

Film thickness

Int. Ø

Length

Specifications

Compare models
HS Code #
90279000
Film thickness
0.50 µm
Int. Ø
0.25 mm
Length
60 m
Material column
Quartz glass
Max. temperature programme
300 °C
Polarity
Mid-polar
Temperature max. isotherm
280 °C
UNSPSC
41115710
USP listing
G46

NZ $3137.72

Inc. GST

Available soon

Product description

The Macherey-Nagel Capillary Column Optima 1701 (ID 0.25 mm, Film Thickness 0.5 µm, Length 60 m) is designed for high-resolution gas chromatography of polar and semi-polar compounds. With its excellent thermal stability and low bleeding characteristics, it ensures superior separation of complex samples. This column is ideal for environmental, food safety, and chemical analysis, delivering reliable and precise results.

Key Features:

  • Brand: Macherey-Nagel
  • Column Type: Capillary column for gas chromatography
  • Inner Diameter: 0.25 mm
  • Film Thickness: 0.5 µm
  • Length: 60 m
  • Phase: Optima 1701 stationary phase for polar and semi-polar compounds
  • Application: Ideal for environmental, food safety, and chemical analysis

Macherey-Nagel’s Capillary Column Optima 1701 is built for high-performance separations and precise analysis in gas chromatography applications.

Downloads

Compare similar models

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.5 µm length: 60 m

Manufacturer P/N

726064.60

Part Number

4.003 040

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726064.30

Part Number

4.003 039

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.5 µm length: 25 m

Manufacturer P/N

726320.25

Part Number

4.003 107

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726318.30

Part Number

4.003 104

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 25 m

Manufacturer P/N

726824.25

Part Number

4.003 222

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726318.25

Part Number

4.003 103

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726318.60

Part Number

4.003 106

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726058.30

Part Number

4.003 036

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726320.30

Part Number

4.003 108

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 60 m

Manufacturer P/N

726824.60

Part Number

4.003 225

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 25 m

Manufacturer P/N

726929.25

Part Number

4.003 268

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.5 µm length: 50 m

Manufacturer P/N

726320.50

Part Number

4.003 109

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 2 µm length: 25 m

Manufacturer P/N

726735.25

Part Number

4.003 178

Manufacturer

Macherey-Nagel

Film thickness

2.00 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 2 µm length: 50 m

Manufacturer P/N

726735.50

Part Number

4.003 180

Manufacturer

Macherey-Nagel

Film thickness

2.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 50 m

Manufacturer P/N

726824.50

Part Number

4.003 224

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726058.25

Part Number

4.003 035

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726965.30

Part Number

4.003 272

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.50 µm length 60 m

Manufacturer P/N

726320.60

Part Number

7.088 327

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726058.50

Part Number

4.003 037

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726318.50

Part Number

4.003 105

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726058.60

Part Number

4.003 038

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726545.30

Part Number

4.003 173

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 50 m

Manufacturer P/N

726929.50

Part Number

4.003 270

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 30 m

Manufacturer P/N

726824.30

Part Number

4.003 223

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 1 µm length: 25 m

Manufacturer P/N

726545.25

Part Number

4.003 172

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 60 m

Manufacturer P/N

726929.60

Part Number

4.003 271

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 2 µm length: 30 m

Manufacturer P/N

726735.30

Part Number

4.003 179

Manufacturer

Macherey-Nagel

Film thickness

2.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726929.30

Part Number

4.003 269

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Frequently asked questions

It is designed for high-resolution gas chromatography of polar and semi-polar compounds. With its excellent thermal stability and low bleeding characteristics, it ensures superior separation of complex samples. This column is ideal for environmental, food safety, and chemical analysis, delivering reliable and precise results.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator holds its contents in a dry, sealed atmosphere, protecting moisture-sensitive samples and reagents and cooling heated samples without letting them take up water. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

The separating funnel is the go-to tool for liquid-liquid extraction across New Zealand labs, from universities and Crown Research Institutes to environmental, water and food testing. This guide explains what it is, how it works step by step, the main shapes, and how to pick one, with an interactive process demo and finder.

Read full story