Representative Image

Ludwig Schneider Precision-ASTM Hydrometer Type S505HL-14 -20 to +65°C in 1°C, 850-900 in 0.5 kg/m³, 380 mm

Max. measured value

Measured range

Min. measured value

Specifications

Compare models
Colour filling
Blue
Division
0.5
Length
380 mm
Max. measured value
900 kg/m³
Max. temperature
65 °C
Measured range
850 ... 900 kg/m³
Min. measured value
850 kg/m³
Min. temperature
-20 °C
Reference temperature
15 °C
Standard
ASTM E2995-14

NZ $324.05

Inc. GST

Available soon

Product description

The Ludwig Schneider Precision-ASTM Hydrometer Type S505HL-14 is a high-precision instrument designed for measuring the density of liquids in laboratory settings. With a temperature range of -20 to +65°C and a scale division of 1°C, it offers accurate readings essential for various applications. The hydrometer is calibrated to measure density in the range of 850 to 900 kg/m³ with a resolution of 0.5 kg/m³, making it suitable for precise density measurements in research and industrial laboratories.

Key Features:

  • Brand: Ludwig Schneider
  • Temperature Range: -20 to +65°C
  • Scale Division: 1°C
  • Density Range: 850 to 900 kg/m³
  • Resolution: 0.5 kg/m³
  • Length: 380 mm
  • Calibration: Traceable to international standards
  • Application: Ideal for precise density measurements in laboratory environments

This hydrometer is an indispensable tool for laboratories requiring accurate and reliable density measurements of liquids.

Compare similar models

Precision-ASTM-hydrometer type S505HL-14 -20...+65°C in 1°C, 850-900 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222116S

Part Number

6.267 137

Manufacturer

Ludwig Schneider

Max. measured value

900 kg/m³

Precision-ASTM-hydrometer type S500HL-14 -20...+65°C in 1°C, 600-650 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222111S

Part Number

6.267 132

Manufacturer

Ludwig Schneider

Max. measured value

650 kg/m³

Precision-ASTM-hydrometer type S501HL-14 -20...+65°C in 1°C, 650-700 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222112S

Part Number

6.267 133

Manufacturer

Ludwig Schneider

Max. measured value

700 kg/m³

Precision-ASTM-hydrometer type S502HL-14 -20...+65°C in 1°C, 700-750 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222113S

Part Number

6.267 134

Manufacturer

Ludwig Schneider

Max. measured value

750 kg/m³

Precision-ASTM-hydrometer type S503HL-14 -20...+65°C in 1°C, 750-800 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222114S

Part Number

6.267 135

Manufacturer

Ludwig Schneider

Max. measured value

800 kg/m³

Precision-ASTM-hydrometer type S504HL-14 -20...+65°C in 1°C, 800-850 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222115S

Part Number

6.267 136

Manufacturer

Ludwig Schneider

Max. measured value

850 kg/m³

Precision-ASTM-hydrometer type S506HL-14 -20...+65°C in 1°C, 900-950 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222117S

Part Number

6.267 138

Manufacturer

Ludwig Schneider

Max. measured value

950 kg/m³

Precision-ASTM-hydrometer type S507HL-14 -20...+65°C in 1°C, 900-1000 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222118S

Part Number

6.267 139

Manufacturer

Ludwig Schneider

Max. measured value

1000 kg/m³

Precision-ASTM-hydrometer type S508HL-14 -20...+65°C in 1°C, 1000-1050 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222119S

Part Number

6.267 140

Manufacturer

Ludwig Schneider

Max. measured value

1050 kg/m³

Precision-ASTM-hydrometer type S509HL-14 -20...+65°C in 1°C, 1050-1100 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222120S

Part Number

6.267 141

Manufacturer

Ludwig Schneider

Max. measured value

1100 kg/m³

Precision-ASTM-thermometer Type S510HL-14 -20...+65°C in 1°C, 775-825 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222345S

Part Number

6.267 142

Manufacturer

Ludwig Schneider

Max. measured value

825 kg/m³

Frequently asked questions

It is a high-precision instrument designed for measuring the density of liquids in laboratory settings. With a temperature range of -20 to +65°C and a scale division of 1°C, it offers accurate readings essential for various applications. The hydrometer is calibrated to measure density in the range of 850 to 900 kg/m³ with a resolution of 0.5 kg/m³, making it suitable for precise density measurements in research and industrial laboratories.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

1 min read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator holds its contents in a dry, sealed atmosphere, protecting moisture-sensitive samples and reagents and cooling heated samples without letting them take up water. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Separating Funnel? Uses and How It Works

1 min read

What is a Separating Funnel? Uses and How It Works

The separating funnel is the go-to tool for liquid-liquid extraction across New Zealand labs, from universities and Crown Research Institutes to environmental, water and food testing. This guide explains what it is, how it works step by step, the main shapes, and how to pick one, with an interactive process demo and finder.

Read full story

NZ $324.05

Inc. GST