Representative Image

Lenz-Laborglas Distilling Receivers To Anschütz-Thiele, Bent, Capacity 100 ml, Socket/Cone NS 29/32

Cone[s]

Material stopcock

Nominal capacity

Socket[s]

Specifications

Compare models
Cone[s]
NS 29/32
Material
DURAN® tubing
Material stopcock
Glass key
Nominal capacity
100 ml
Socket[s]
NS 29/32
Type of construction
Acc. to Anschütz-Thiele
UNSPSC
41104812
With graduation
Yes

NZ $812.41

Inc. GST

Available soon

Product description

The Lenz-Laborglas Distilling Receivers to Anschütz-Thiele are precision-crafted for reliable distillation in laboratory applications. With a 100 ml capacity, these receivers feature a bent design for easy handling and a socket/cone connection (NS 29/32) for secure fittings. Designed to facilitate efficient liquid collection during distillation, they are ideal for chemical separation, solvent recovery, and other laboratory processes requiring high accuracy and durability.

Key Features:

  • Brand: Lenz-Laborglas
  • Capacity: 100 ml for accurate distillate collection
  • Connection: Socket/Cone NS 29/32 for reliable and secure fittings
  • Design: Bent shape for easy handling and efficient distillation
  • Application: Ideal for distillation, solvent recovery, and laboratory separation tasks

This distilling receiver is an essential tool for laboratories performing distillation processes, ensuring precise collection of liquids and reliable performance during experiments.



Frequently Asked Questions

1. What is the Lenz-Laborglas Distilling Receivers To Anschütz-Thiele, Bent, Capacity 100 ml, Socket/Cone NS 29/32 used for?

It are precision-crafted for reliable distillation in laboratory applications. With a 100 ml capacity, these receivers feature a bent design for easy handling and a socket/cone connection (NS 29/32) for secure fittings. Designed to facilitate efficient liquid collection during distillation, they are ideal for chemical separation, solvent recovery, and other laboratory processes requiring high accuracy and durability.

2. Is this product suitable for distillation, solvent recovery, and laboratory separation tasks?

Yes. It is designed for distillation, solvent recovery, and laboratory separation tasks, and offers a capacity of 100 ml for accurate distillate collection to support this kind of work.

3. What capacity does this product have?

It has a capacity of 100 ml for accurate distillate collection.

4. What connection and design does this product offer?

It offers socket/Cone NS 29/32 for reliable and secure fittings and bent shape for easy handling and efficient distillation.

Compare similar models

Distilling Receivers to Anschütz-Thiele, Bent  , Cap. ml 100 Socket/Cone NS 29/32

Manufacturer P/N

05298014

Part Number

6.225 604

Manufacturer

Lenz-Laborglas

Cone[s]

NS 29/32

Distilling Receivers to Anschütz-Thiele, Bent, Cap. ml 50 Socket/Cone NS 29/32

Manufacturer P/N

05298104

Part Number

6.202 415

Manufacturer

Lenz-Laborglas

Cone[s]

NS 29/32

Distilling Receivers to Anschütz-Thiele, Bent, Cap. ml 25 Socket/Cone NS 14/23

Manufacturer P/N

05298001

Part Number

9.012 641

Manufacturer

Lenz-Laborglas

Cone[s]

NS 14/23

Distilling Receivers to Anschütz-Thiele, Bent, Cap. ml 50 Socket/Cone NS 29/32

Manufacturer P/N

05298004

Part Number

9.012 643

Manufacturer

Lenz-Laborglas

Cone[s]

NS 29/32

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NZ $812.41

Inc. GST