Representative Image

Behr Labor-Technik Infrared Rapid Sample Digestor InKjel 475 M, with Manual Power Control for 4x750ml Sample Vessels

Max. no. of sample positions

Type

Specifications

Compare models
HS Code #
84198998
Amperage
8 A
Power supply frequency
50/60 Hz
Height
750 mm
Max. no. of sample positions
4
Max. temperature
410 °C
Max. voltage
230 V·AC
Power supply
230 V·AC, 50/60 Hz , 8 A
Rated capacity
1500 W
Type
InKjel 475 M
UNSPSC
41104815

NZ $11952.92

Inc. GST

Available soon

Product description

The Behr Labor-Technik Infrared Rapid Sample Digestor InKjel 475 M is designed to handle up to four 750ml sample vessels, providing efficient and reliable digestion for Kjeldahl nitrogen analysis. Equipped with manual power control, this unit offers precise operation, allowing laboratories to customize digestion times and temperatures based on specific sample requirements. With infrared heating technology, the InKjel 475 M ensures rapid and consistent results, making it an essential tool for high-throughput laboratories performing nitrogen determination.

Key Features:

  • Brand: Behr Labor-Technik
  • Capacity: Supports 4 sample vessels of 750ml each
  • Power Control: Manual power control for flexible and precise operation
  • Technology: Infrared heating for rapid and efficient digestion
  • Application: Ideal for Kjeldahl nitrogen analysis in laboratories
  • Material: Built for durability and reliability

The Behr Labor-Technik InKjel 475 M is a powerful tool for laboratories requiring efficient and precise sample digestion, offering rapid results and full control during Kjeldahl nitrogen analysis.

Accessories

Accessories for Kjeldahl rapid sample digestors

ProductTypeDescriptionMfr#Part#AvailabilityPrice
SR 3iSample vessel, 250ml, for InKjel*B002179599.843 766In stockNZ $152.28
SR 5Sample vessel 500ml, for K8 B*B003731709.843 751NZ $355.32
AFSAntifoam tabletsB002179369.843 753NZ $1056.30
WPNitrogen-free weighing boatsB004411369.843 754NZ $137.78
KJ 500Sample vessel, 500ml, for InKjel*B002181959.843 775NZ $374.66
SR 4Sample vessel 100ml, for InKjel*B002179609.843 750NZ $111.19
EG 4/ 500Vessel holding frame for four 500ml vessels. Component of InKjel 450 M and PB002180859.843 790NZ $913.69
EG 12Vessel holding frame for twelve 250ml vessels. Component of InKjel 1225 M and PB002180879.843 789NZ $1261.76
AE 4Fume exhaust manifold for InKjel 450 and 475 (M and P)B002180889.843 792NZ $2156.12
EG 6Vessel holding frame for six 250ml vessels. Component of InKjel 625 M and PB002180869.843 788NZ $913.69
EG 4/ 750Vessel holding frame for four 750ml vessels. Component of InKjel 475 M and PB002180809.843 791NZ $923.36
KJ 750Sample vessel, 750ml, for InKjel*B002182189.843 776NZ $394.00
AE12Fume exhaust manifold for InKjel 1225 (M and P)B002180909.843 794NZ $3666.85
AE 6Fume exhaust manifold for InKjel 625 (M and P)B002180899.843 793NZ $2257.64

Compare similar models

Infrared rapid sample digestor InKjel 475 M with manual power sontrol, for 4x750ml sample vessels

Manufacturer P/N

B00218068

Part Number

9.843 769

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Infrared rapid sample digestor with manual power control InKjel 1225M for 12x250ml sample vessels

Manufacturer P/N

B00218103

Part Number

9.843 771

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Rapid infrared digestion unit InKjel 1210 M for 12 sample vessels of 100 ml

Manufacturer P/N

B00373235

Part Number

9.843 757

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Infrared rapid sample digestor InKjel 450 M with manual power control, for 4x500ml sample vessels

Manufacturer P/N

B00218067

Part Number

9.843 768

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Infrared rapid sample digestor with manual power control InKjel 625M for 6x250ml sample vessels

Manufacturer P/N

B00218101

Part Number

9.843 770

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

6

Frequently asked questions

It is designed to handle up to four 750ml sample vessels, providing efficient and reliable digestion for Kjeldahl nitrogen analysis. Equipped with manual power control, this unit offers precise operation, allowing laboratories to customize digestion times and temperatures based on specific sample requirements. With infrared heating technology, the InKjel 475 M ensures rapid and consistent results, making it an essential tool for high-throughput laboratories performing nitrogen determination.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator holds its contents in a dry, sealed atmosphere, protecting moisture-sensitive samples and reagents and cooling heated samples without letting them take up water. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

The separating funnel is the go-to tool for liquid-liquid extraction across New Zealand labs, from universities and Crown Research Institutes to environmental, water and food testing. This guide explains what it is, how it works step by step, the main shapes, and how to pick one, with an interactive process demo and finder.

Read full story