Microlitre Syringes

The Microlitre Syringes category covers equipment and consumables used to separate, identify and quantify components in complex samples using controlled flow paths, columns, gases, detectors and supporting sample hardware. These products are not isolated purchases, because their performance is tied to the sample, surrounding equipment and the way the wider method is carried out.


Leaks, contamination, unsuitable materials or poorly matched consumables can reduce sensitivity and make retention or identification less reliable. The practical choice therefore depends on purity or cleanliness grade, instrument connection, analytical technique, and sample chemistry, as well as how frequently the product will be used and how it connects with the rest of the procedure.


The complete method includes sample preparation, compatible vials or tubes, a stable carrier or mobile phase, separation hardware, detection and appropriate data review. Looking at the full sequence makes it easier to identify the correct accessories and consumables before the equipment is put into service in pharmaceutical, chemical, food, environmental, forensic and research laboratories. As part of the Chromatography Equipment & Supplies range, these products can be selected with the equipment and consumables used before and after this stage.


Our Microlitre Syringes range

Our collection covers cleaning precision microlitre syringe, hamilton microliter and gastight syringes, choose a removable needle (rn) over a cemented needle (n), and microlitre syringes accessories and workflow integration, giving laboratories practical choices for routine work and more specialised applications.


Cleaning precision microlitre syringe

Syringes should be rinsed immediately after use with a solvent that dissolves the sample, followed by a high-volatility solvent like acetone, and dried with clean air or vacuum. For routine and specialised work, assess purity or cleanliness grade, instrument connection, and analytical technique. Matching these points early helps avoid adapters, consumables or operating limitations being discovered after purchase. This is especially valuable when teams need to keep the analytical flow path compatible, clean and reproducible from sample introduction to detection. Consistent handling also reduces the risk of variation between batches or operators.


Hamilton Microliter and Gastight syringes

Microliter syringes (like the 700 series) use a stainless steel plunger hand-fitted to the glass barrel, while Gastight syringes (like the 1000 series) feature a PTFE plunger tip for a superior seal with gases and volatile liquids. When comparing options, consider instrument connection, analytical technique, and sample chemistry. The correct choice should fit the sample, expected workload and any equipment already used in the method. Used correctly, this part of the range helps laboratories keep the analytical flow path compatible, clean and reproducible from sample introduction to detection. The result is a setup that is easier to train, document and maintain.


Choose a Removable Needle (RN) over a Cemented Needle (N)

RN syringes allow you to replace a bent needle without discarding the expensive syringe barrel, and they offer the flexibility to use different needle lengths or tip styles (point styles). For routine and specialised work, assess analytical technique, sample chemistry, and pressure and flow requirements. Matching these points early helps avoid adapters, consumables or operating limitations being discovered after purchase. In practice, this supports efforts to keep the analytical flow path compatible, clean and reproducible from sample introduction to detection. It also gives staff a clearer and more repeatable procedure when multiple users or shifts share the same equipment.


Microlitre Syringes accessories and workflow integration

"KH" stands for Knurled Hub, a specialised design that allows for the precise replacement of the plunger and needle assembly in ultra-low volume syringes. The most suitable format depends on sample chemistry, pressure and flow requirements, and material compatibility. Laboratories should also confirm how the product will be prepared, used, cleaned or disposed of between runs. Within the wider method, these products help laboratories keep the analytical flow path compatible, clean and reproducible from sample introduction to detection. They should be reviewed together with associated consumables, accessories and cleaning requirements.


Featured brands

DWK Life Sciences is known for laboratory glassware, bottles and precision handling products, BRAND is known for liquid-handling products, volumetric labware and supporting accessories, LLG Labware is known for practical laboratory consumables, accessories and routine bench supplies, and Thermo Scientific is known for analytical, life-science and general laboratory instrumentation. Compare each brand by purity or cleanliness grade, instrument connection, analytical technique, and sample chemistry, and check what is included with the product so the complete setup is clear before ordering.


Why choose LabFriend for Microlitre Syringes

At LabFriend, we are committed to helping Australian laboratories select laboratory microlitre syringes around the actual method, not simply the most prominent specification. Our knowledgeable team can assist with purity or cleanliness grade, instrument connection, analytical technique, and sample chemistry, and can help identify the accessories or consumables needed to make the setup workable from the first use. As a 100% online laboratory supplier, we provide competitive pricing, transparent lead times and a convenient way to compare connected products in one place.


Whether the requirement is a new installation, a replacement unit or routine replenishment, the laboratory microlitre syringes range can be combined with supporting products for a more complete setup. Useful related areas include Disposable Syringes and Chromatography Syringes for Labs, which can help complete the surrounding workflow. Sourcing these connected items together helps protect continuity and reduces the chance that a small missing component will delay the work. Add the selected products to your cart and select Instant Quote.

Showing 257 - 286 of 286 results

Microliter syringe 1710 N (22s/51/3) 100 µl
Available soon
Microliter syringe 1725 N (22s/51/3) 250 µl
Available soon
Microliter syringe 1702 N (22s/51/3) 25 µl
Available soon
Microliter syringe 1702 N (22s/51/5) 25 µl
Available soon
Microliter syringe 1702 RNR (22s/51/3) 25 µl
Available soon
Microliter syringe 1750 SL (22/51/2)L, 500 µl
Available soon
Microliter syringe 1705 N (22s/51/3) 50 µl
Available soon
LLG-Glass-Syringe, 5ml with metal LUERLOCK pack of 5
Available soon
LLG-Glass-Syringe, 20ml with metal LUERLOCK pack of 5
Available soon
LLG-Glass-Syringe, 2ml with metal LUERLOCK pack of 5
Available soon
LLG-Glass-Syringe, 50ml with metal LUERLOCK pack of 5
Available soon
Microlitre syringes 801 RN 10ul
Available soon
Part
•
Microliter syringe 1025 TLL 25 ml, with metal flange
Available soon
Microliter syringe 1725 RNR (22/51/3) 250 µl
Available soon
Microliter syringe 1725 RN (22s/51/2) 250 µl
Available soon
Microliter syringe 1725 SL (22s/51/2)L, 250 µl
Available soon
Needle 10 µl, N10-5 pack of 5
Available soon
Part
•
Needles N10-5/0.63C pack of 2
Available soon
Part
•
Needle 10 µl, N10-7 pack of 5
Available soon
Part
•
Needle 10 µl, N10-11.5 pack of 5
Available soon
Microliter syringe 1701 RN (33s/20/3) 10 µl
Available soon
Microlitre syringe NRS 1702 RN (33/20/3) 25 µl
Available soon
Microlitre syringe NRS 1710 RN (33/20/3) 100 µl
Available soon
Microlitre syringe NRS 1705 RN (33/20/3) 50 µl
Available soon
Syringe 5µl, 5R-GP
Available soon
Part
•
syringe 10R-GP 10 µl
Available soon
Part
•

Frequently asked questions

Syringes should be rinsed immediately after use with a solvent that dissolves the sample, followed by a high-volatility solvent like acetone, and dried with clean air or vacuum. Laboratories should compare sample chemistry, pressure and flow requirements, and material compatibility and document the selected setup for consistent use.